Sensing Info 传感器资讯   

Tip of my blog

   www.xgmh88.com
www.bxj688.com
www.mrzzg.com
www.750127.com

特别声明:本博客内容不允许随意转载,有需要请联系,如果本博客内容损害了您的权利,请联系我,我们会做相关处理或删除.

更多更详细的内容请点击

New态氧分压变送器(氧含量分析仪) ZH420-O推出

世界知名的气体分析监控仪表传感器,在气体仪器仪表行业我们将提供更全面更专业的技术支持和服务,并提供更优秀的产品.


阅读(6073) 评论(78)
标签(TAG):oxygen sensor O2S

FEATURES

· Oxygen pressure range 2 mbar...3 bar

· Zirconium dioxide (ZrO2 ) sensing elements

由于工厂产品型号扩大范围,原命名系统不能完全包含,为了型号的统一性工厂做了重新命名。如任何问题和疑问请联系本站
O2S-FR-T4/ O2S-FR-T4-4P/ O2S-FR-T2/ O2S-FR-T2-18A/ O2S-FR-T3/O2S-T6/O2S-T6-SH/O2S-T2/O2S-T3

O2S Series

Oxygen sensors


· Non-consumptive technology

· Integral heating element

· No need for temperature stabilisation

· No reference gas required

· Function testing and calibration in

ambient air

· High accuracy

· Linear output signal

· Operates with external interface boards

响应时间小于4秒,具体资料和问题请咨询本版主

by admin 发表于:2007/8/11 7:35:09
回复:oxygen sensor  of  X
引用 | 举报回复

At temperatures above 6500C Zirconium Dioxide (ZrO2 ) exhibits two mechanisms:

Firstly, it partly dissociates, producing mobile oxygen ions within the material. Normally moving at random, these ions can be transported through the piece of ZrO2 when a DC voltage is applied across the material. This liberates an amount of oxygen at the anode proportional to the charge transported (electrochemical pumping action).

Secondly, when there is an oxygen pressure difference across a piece of ZrO2 a voltage (the Nernst voltage) is generated across it. This voltage is proportional to the natural logarithm of the ratio of the oxygen pressure on each side of the material.

These mechanisms are used in a number of oxygen sensors but our sensor makes use of both simultaneously. This removes the need for a reference pressure which simplifies the sensor operation.

Our sensor contains 2 pieces of ZrO2 with a small hermetically sealed chamber between them. One of the discs functions as a reversible oxygen pump, which is used to successively fill and empty the chamber. The second disc measures the ratio of the oxygen partial pressure difference and generates a corresponding sense voltage. A heater surrounding the sensing element produces the 7000C required for the ZrO2 to act as a pump.

The time taken for the pump to achieve specific minimum and maximum pressures within the chamber is a measure of the partial pressure of oxygen in the environment. Al2O3 discs filter particulate matter and neutralize un-burnt gasses to avoid contamination, which might lead to unstable readings.

by advsensors 发表于:2007/8/11 18:16:17
My subject | 我的主题

New entries | 新发表

Messages Board | 留言板


Guest Comments | 新评注


Blogger Login | 登陆栏
Blog Infomation | 信息栏
博客名称:传感器资讯博客-Sensing Info 日志总数:102 评论数量:40 访问次数:541120 建立时间::2006年01月16日
Blog Infomation | 搜索栏
Blog Infomation | 收藏栏

XML RSS 2.0

传感器资讯博客-Sensing Info
© COPYRIGHT 2004 ALL RIGHTS RESERVED http://www.eyflu.com.cn/

中华工控网 | 联系我们 | 工控论坛首页 | 首页 | 博客注册 | 博客登陆

工控博客管理联系邮箱:工控博客服务邮箱

中华工控网 © Copyright 2013. All rights reserved.

重庆欢乐十分开奖查询 澳洲幸运5官网是多少 幸运飞艇是官方开奖吗 江西时时彩在线缩水 河北快三开奖结果遗漏
彩票甘肃新十一选五 博彩通 排球比赛图片 时时彩万位6码100% 天津福彩快乐十分走势
河北11选五走势图表 吉林快3二不同走势图 冰球打架 天津快乐十分开奖结果 辽宁风采35选7走势图
安徽体彩11选5最大遗漏 广东南粵36选7走势图 重庆时时彩龙虎口诀 象棋视频 赌博默示录2